Indizone Pharmaline Series

Designed for continuous ozone generation in critical process applications that require medium and high concentration ozone production, our INDIZONE Pharmaline series is meant for easy and effective diagnosis and installation. We provide a range of options requiring low maintenance for your purification purposes.

Advantages of Indizone Pharmaline series:

  • All critical parameters of the ozone generator are monitored and displayed for easy health diagnosis
  • Intuitive HMI allows maximum flexibility of ozone production
  • Intelligent sensors with self-diagnosis offer unmatched reliability
  • Easy integration with master PLCs and SCADA
  • Factory tested (Full load) plug and play system for quick and easy installation
  • Highest MTBF
  • Patented design allows online ozone production indication and control
  • 7’’ intuitive Touch screen HMI for health diagnosis
  • Fully Automated, hands-free operation through sophisticated PLC control
  • Online ozone production indication
  • 2nd Generation EOPITM electrodes for standard applications
  • 3rd Generation Dual Micro channel TM electrodes for high concentration applications
  • 3 intelligent sensors for flow, temperature and power measurement
    IP54 rating
  • CE and ISO certification

Problem: A multi-faceted India based healthcare organization faced the problems of pathogen reactivation/resistance to chlorine. We offered the solution of ozone at pre-treatment with precise dosing and contact-time measurement to replace chlorine as the disinfectant of choice. Dosage studies at 1.0-3.0 ppm achieving 100-300 ppb residual ozone were carried out with 2 different contact tank volumes.

Solution:
 Third party microbiological tests confirmed precise dosage, contact time and residual needed to combat the specific strain of pseudomonas.

Problem: A European multinational food-products corporation with unique health-focused portfolio in food and beverages faced the problem of removal of specific micro-contaminants for process water while adhering to international standards of DBP and Bromate formation control. We conducted a lab study for proof of concept of micro-contaminant removal at ozone dosage of 1.0-5.0 ppm in pure water, followed by pilot plant at site with precise contaminant measurement in actual process water. This was further followed by full-scale ozone at pre-treatment with precise and calibrated dosing rates.

Solution:
 A government spine institute faced the issue to reduce time between operations by improving the existing disinfection strategy. We provided full-scale testing with Air-Ozonation with third party swap tests for proof of concept at ozone residuals of 100-300 ppb and sterilization times varying from 30-45 minutes. This was followed by fully automated Ozone dosing and sensor-based controllers to adhere to international safety norms.

Problem: An India-based global pharmaceutical major faced the problem of water contamination post UV-destruction, despite the seemingly high ozone dosage from previously installed ozone system by another contractor.

Solution:
 Our solution was Node by Node testing which showed low ozone residual at tank outlet despite high ozone generator rated production (>10 ppm). The pathogen absence at tank outlet seemed counterintuitive, but the pathogen presence post UV-destruction provided some answers. A new ozone generator (5ppm) was installed with improved mixing strategy which allowed the client to re-start plant operations in the quickest possible time.

General information Specification
Ozone concentration Upto 10% w/w
Cooling method Air cooling/ Water cooling
Feed gas PSA/VSA/LOX
Feed gas inlet pressure 1 bar
System options Skid mounted / Wall mounted
System components Specification
System control Siemens/Allen Bradley/Selectron
MOC Specification
Ozone dielectric Glass/SS316/Enamel
Water contact parts SS316/Teflon
Panel MS dip coated/ SS304
Safety features Specification
Velocity transmitter 0-300 cm/sec/ 4-20ma with adjustable response time and attenuation Over range and under range self diagnosis
Temperature switch/transmitter Adjustable NO/NC or 4-20 ma temperature sensor/transmitter with switch on delay
Current transmitter As required by model
Voltage protection & SMPS As required by model
HV cable 22KV lapp
Certification & Rating Specification
Certification CE/ISO
Rating Max IP54

Available Products

  • Ozonia CFS Series Ozone Generators

    Overview
    The Ozonia CFS-2G is SUEZ’s latest ozone generator system for small to medium sized water treatment applications.
  • Ozone Mixing Systems

    Overview
    Venturies, diffusers, static mixers and liquid gas compressors for enhanced ozone mixing.
  • Ozone Gas Analysers

    Overview
    High concentration ozone analyser, splash-proof aluminium enclosure, cTUVus certified, throttle
  • Dissolved Ozone Sensors

    Overview
    Robust and accurate inline and portable dissolved ozone analysers..
  • Ozone Sensors

    Ambient Ozone Sensors

    Overview
    Industrial sensors and transmitters for precise measurement of ozone gas in plant rooms and enclosed spaces.